Service & Configuration
Updated September 2022
 
Type: 
Configuration: 
HC Liquid Outlet Nozzles:      Inlet Distributor
Temperature, F: 
Fluid Rates & Properties
      Vapor Liquid (ex water) (liquid)
Flow, lb/hr:           
Density,  lb/ft3:          
Viscosity, cP:         
Vessel Parameters
Diameter, inches:               Nozzle Inlet Vapor Outlet
Length, ft.:           Size, inches    
Recom Max Vel, ft/sec 49.1 70.7
Outboard Noz. to Noz, ft.:      Velocity, ft/sec 58 84.6
Low Level, inches:      RhoV2, lb/ft-sec2 2514 3583
High Level, inches:      
Liquid residence min: 6 Liquid Vol, cu. ft.: 281.49 0.288 Vol. frac water  
Boot Parameters
Boot Diameter, inches:     Water Velocity, In./min
Boot LC Range, inches:      HC Rise, In./min 6.4 125 micron drop
  Water Holdup,min
Rating Parameters
Theo .Sep. Droplet :    181    microns Liquid Nozzle HC Outlet Water Outlet
Mist Eliminator:  Size, inches
Design pressure psig:    Rec Max Vel., ft/sec 3 3
Operating pressure psia:    Velocity, ft/sec 2.83 4.57
Mesh/Vane Design K:   0.32  ft/sec RhoV2, lb/ft-sec2 400 1293
Vessel top to Mesh Btm., in.:   
Calculated Results
Vapor X-Flow Area 17.12 ft2 X-Flow Area Below Mesh: 11.6 ft2
Vapor X-Flow K: 0.98 ft/sec Max Vapor K Recommended: 0.4 ft/sec
Vapor X-flow Velocity: 9.73 ft/sec  Max Vapor X-flow Vel. Recom.: 4 ft/sec
Mesh/Vane Area 51.88 ft2
Area Under Demister is too Small   Vapor x-flow Velocity is too High
Mesh Support top Chord 54 inches Mesh Support Bottom Chord: 62 inches
    Water Settling Rate 7.7 in./min.
Vessel Cost Index: 13,300